{"id":7401,"date":"2026-09-03T15:40:56","date_gmt":"2026-09-03T13:40:56","guid":{"rendered":"https:\/\/cleverpoint.pro\/docs\/uncategorized\/sektor-4\/"},"modified":"2026-09-03T15:40:56","modified_gmt":"2026-09-03T13:40:56","password":"","slug":"sektor-4","status":"publish","type":"docs","link":"https:\/\/cleverpoint.pro\/pl\/docs\/rozdzial-2-cardio-domain\/sektor-4\/","title":{"rendered":"Sektor 4"},"content":{"rendered":"\n<p>Sektor 4 wy\u015bwietla wykres automatycznie wykrytych za\u0142amk\u00f3w R na EKG, a po aktywowaniu odpowiedniej kom\u00f3rki w sektorze 1 (patrz Rys. 2.2a) wy\u015bwietla r\u00f3wnie\u017c sam\u0105 krzyw\u0105 EKG. Zapoznali\u015bmy si\u0119 ju\u017c z t\u0105 cz\u0119\u015bci\u0105 (patrz podrozdzia\u0142y: \u201eSektor 1.1\u201d, \u201eSektor 1.2\u201d, \u201eSektor 1.4\u201d). Zasadniczo funkcja tego sektora zosta\u0142a ju\u017c opisana i zrozumiana. Pozostaje, na przyk\u0142adzie kilku zapis\u00f3w EKG w sektorze 4, przyjrze\u0107 si\u0119 pracy z ikonami funkcyjnymi, kt\u00f3re kr\u00f3tko opisali\u015bmy w Rozdziale 1.<\/p>\n\n\n\n<p class=\"note\">Od razu zaznaczmy, \u017ce r\u0119czne przetwarzanie EKG \u2014 na przyk\u0142ad obliczanie odst\u0119p\u00f3w lub charakterystyk amplitudowych \u2014 najlepiej przeprowadza\u0107 na stronie \u201eTime domain\u201d.<\/p>\n\n\n\n<p>Zacznijmy od ju\u017c znanej ikony \u201e+\u201d \u2013 \u201eZoom In\u201d (Rys. 1.8f). Po aktywowaniu tej ikony (aktywna ikona jest pod\u015bwietlona na niebiesko), je\u015bli przesuniesz kursor nad obrazem w sektorze 4 i klikniesz prawym przyciskiem myszy, pojawi si\u0119 okno z list\u0105 dalszych dzia\u0142a\u0144 (Rys. 2.11a). Domy\u015blnie (wybrana linia jest dodatkowo pod\u015bwietlana, gdy znajduje si\u0119 nad ni\u0105 kursor) aktywna jest funkcja pozwalaj\u0105ca powi\u0119ksza\u0107 obraz zar\u00f3wno w poziomie (powi\u0119kszanie poziome omawiali\u015bmy przy opisie podrozdzia\u0142u \u201eSektor 1.4\u201d), jak i w pionie. Wyb\u00f3r kierunku nale\u017cy do Ciebie. Je\u015bli, przytrzymuj\u0105c lewy przycisk myszy, zaznaczysz odcinek poziomo, EKG zostanie rozci\u0105gni\u0119te w poziomie, czyli wzd\u0142u\u017c osi czasu (Rys. 2.11c, d); je\u015bli zaznaczysz odcinek EKG w pionie, EKG zostanie powi\u0119kszone na ekranie pod wzgl\u0119dem amplitudy w wybranym zakresie w oknie sektora (Rys. 2.11e, f).<\/p>\n\n\n\n<figure class=\"wp-block-image size-full border\"><img data-dominant-color=\"5a615c\" data-has-transparency=\"true\" style=\"--dominant-color: #5a615c;\" loading=\"lazy\" decoding=\"async\" width=\"1473\" height=\"605\" src=\"https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-20.png\" alt=\"Six-panel sequence of ECG waveform zoom operations in sector 4: a right-click context menu with Zoom Out, Restore View, and Unconstrained\/Horizontal\/Vertical Zoom options, followed by progressively zoomed-in green ECG traces illustrating horizontal (time-scale) and vertical (amplitude) stretching.\" class=\"wp-image-4579 has-transparency\" srcset=\"https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-20.png 1473w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-20-300x123.png 300w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-20-768x315.png 768w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-20-360x148.png 360w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-20-150x62.png 150w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-20-480x197.png 480w\" sizes=\"auto, (max-width:767px) 480px, (max-width:1473px) 100vw, 1473px\" \/><\/figure>\n\n\n\n<p class=\"doc-image-note\">Rysunek 2.11. Mo\u017cliwo\u015bci zmiany skalowania obrazu w sektorze 4 przy domy\u015blnie aktywnej ikonie \u201e+\u201d lub przy aktywowanej linii \u201eUnconstrained Zoom\u201d (wyja\u015bnienia w tek\u015bcie)<\/p>\n\n\n\n<p class=\"warning\">Wszystkie te czynno\u015bci mo\u017cna wykona\u0107 od razu po aktywowaniu ikony \u201e+\u201d, bez wywo\u0142ywania opisanego wy\u017cej okna. Powtarzamy: linia \u201eUnconstrained Zoom\u201d jest aktywna domy\u015blnie.<\/p>\n\n\n\n<p>Czasem taka funkcja komu\u015b nie odpowiada. W\u00f3wczas, aktywuj\u0105c linie \u201eHorizontal Zoom\u201d (Rys. 2.12a) i\/lub \u201eVertical Zoom\u201d (Rys. 2.12c), mo\u017cesz wybra\u0107 wymagany kierunek skalowania; w takim przypadku kursor nie b\u0119dzie mia\u0142 kszta\u0142tu krzy\u017cyka (Rys. 2.11b), lecz strza\u0142ek wskazuj\u0105cych wybrany kierunek (Rys. 2.11b i d).<\/p>\n\n\n\n<figure class=\"wp-block-image size-full border\"><img data-dominant-color=\"727a76\" data-has-transparency=\"true\" style=\"--dominant-color: #727a76;\" loading=\"lazy\" decoding=\"async\" width=\"1471\" height=\"276\" src=\"https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-21.png\" alt=\"Four-panel close-up of ECG zoom controls: right-click context menus with 'Horizontal Zoom' (a) and 'Vertical Zoom' (c) selected, each followed by the corresponding zoomed ECG trace showing the cursor changed to a horizontal double-arrow (b) or vertical double-arrow (d) icon.\" class=\"wp-image-4582 has-transparency\" srcset=\"https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-21.png 1471w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-21-300x56.png 300w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-21-768x144.png 768w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-21-360x68.png 360w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-21-150x28.png 150w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-21-480x90.png 480w\" sizes=\"auto, (max-width:767px) 480px, (max-width:1471px) 100vw, 1471px\" \/><\/figure>\n\n\n\n<p class=\"doc-image-note\">Rysunek 2.12. Mo\u017cliwo\u015bci zmiany skalowania obrazu w sektorze 4 przy aktywowanych liniach \u201eHorizontal Zoom\u201d i \u201eVertical Zoom\u201d (wyja\u015bnienia w tek\u015bcie)<\/p>\n\n\n\n<p>Linia \u201eZoom Out\u201d aktywuje si\u0119 po klikni\u0119ciu na ni\u0105 (Rys. 2.13c). W takim przypadku wcze\u015bniej wykonane skalowanie jest cofane krok po kroku (Rys. 2.13a \u2013 rozci\u0105gni\u0119cie osi czasu; patrz Rys. 2.13 od b do d) (Rys. 2.13e, f).<\/p>\n\n\n\n<figure class=\"wp-block-image size-full border\"><img data-dominant-color=\"5f6661\" data-has-transparency=\"true\" style=\"--dominant-color: #5f6661;\" loading=\"lazy\" decoding=\"async\" width=\"1471\" height=\"776\" src=\"https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-22.png\" alt=\"Sequence of ECG sector 4 views (a-f) showing the right-click zoom context menu with Zoom Out, Restore View, Horizontal Zoom, and Vertical Zoom options, and the resulting time-scale changes on the green ECG trace as a previous zoom is cancelled step by step.\" class=\"wp-image-4585 has-transparency\" srcset=\"https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-22.png 1471w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-22-300x158.png 300w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-22-768x405.png 768w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-22-360x190.png 360w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-22-142x75.png 142w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-22-480x253.png 480w\" sizes=\"auto, (max-width:767px) 480px, (max-width:1471px) 100vw, 1471px\" \/><\/figure>\n\n\n\n<p class=\"doc-image-note\">Rysunek 2.13. Zmiany skalowania obrazu w sektorze 4 przy aktywowanej linii \u201eZoom Out\u201d (wyja\u015bnienia w tek\u015bcie)<\/p>\n\n\n\n<p>Konieczno\u015b\u0107 wielokrotnego aktywowania linii \u201eZoom Out\u201d nie zawsze jest wygodna. Dlatego mo\u017cesz klikn\u0105\u0107 (aktywowa\u0107) lini\u0119 \u201eRestore View\u201d (Rys. 2.14a) i wr\u00f3ci\u0107 do obrazu w sektorze 4, jaki pojawia si\u0119 po wczytaniu pliku (Rys. 2.14b), a nast\u0119pnie, aktywuj\u0105c ikon\u0119 \u201e+\u201d, wr\u00f3ci\u0107 do wymaganego momentu w czasie i po\u017c\u0105danego poziomu powi\u0119kszenia.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full border\"><img data-dominant-color=\"42b06a\" data-has-transparency=\"true\" style=\"--dominant-color: #42b06a;\" loading=\"lazy\" decoding=\"async\" width=\"1470\" height=\"288\" src=\"https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-23.png\" alt=\"Right-click zoom context menu with &quot;Restore View&quot; highlighted (a) and the resulting full-width sector 4 signal view after restoring to the default zoom level (b).\" class=\"wp-image-4588 has-transparency\" srcset=\"https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-23.png 1470w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-23-300x59.png 300w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-23-768x150.png 768w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-23-360x71.png 360w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-23-150x29.png 150w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-23-480x94.png 480w\" sizes=\"auto, (max-width:767px) 480px, (max-width:1470px) 100vw, 1470px\" \/><\/figure>\n\n\n\n<p class=\"doc-image-note\">Rysunek 2.14. Zmiany powi\u0119kszenia obrazu w sektorze 4 przy aktywowanej linii \u201eRestore View\u201d (patrz wyja\u015bnienie w tek\u015bcie)<\/p>\n\n\n\n<p><br>Ten sam efekt powrotu do bardziej skompresowanej osi czasu lub amplitudy sygna\u0142u EKG mo\u017cna uzyska\u0107, aktywuj\u0105c ikon\u0119 \u201e-\u201d \u2013 \u201eZoom Out\u201d (Rys. 1.8g). W takim przypadku pojawiaj\u0105ce si\u0119 dodatkowe okno (Rys. 2.11a) b\u0119dzie takie samo. Kursory b\u0119d\u0105 mia\u0142y jednak znak \u201e-\u201d (Rys. 2.15). Klikni\u0119cie kursorem bez strza\u0142ek (Rys. 2.15a) zmniejszy krok po kroku zar\u00f3wno skal\u0119 pionow\u0105, jak i poziom\u0105; ze strza\u0142kami poziomymi (Rys. 2.15b) \u2013 skal\u0119 czasu; ze strza\u0142kami pionowymi (Rys. 2.15c) \u2013 skal\u0119 amplitudy.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full border\"><img data-dominant-color=\"555f57\" data-has-transparency=\"true\" style=\"--dominant-color: #555f57;\" loading=\"lazy\" decoding=\"async\" width=\"1811\" height=\"376\" src=\"https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-24.png\" alt=\"Three zoom-out cursor variants on the ECG trace in sector 4: a plain minus cursor for scaling both axes (a), a minus cursor with horizontal arrows for time-scale-only zoom (b), and a minus cursor with vertical arrows for amplitude-scale-only zoom (c).\" class=\"wp-image-4591 has-transparency\" srcset=\"https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-24.png 1811w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-24-300x62.png 300w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-24-768x159.png 768w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-24-1536x319.png 1536w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-24-360x75.png 360w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-24-150x31.png 150w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-24-480x100.png 480w\" sizes=\"auto, (max-width:767px) 480px, (max-width:1811px) 100vw, 1811px\" \/><\/figure>\n\n\n\n<p class=\"doc-image-note\">Rysunek 2.15. Kursory przy aktywnej ikonie \u201e-\u201d: a \u2013 gdy aktywowana jest linia \u201eUnconstrained Zoom\u201d; b \u2013 linia \u201eHorizontal Zoom\u201d; c \u2013 linia \u201eVertical Zoom\u201d<\/p>\n\n\n\n<p>Ten sam efekt co przy linii \u201eRestore View\u201d mo\u017cna uzyska\u0107, aktywuj\u0105c ikon\u0119 z domkiem, kt\u00f3ra r\u00f3wnie\u017c nazywa si\u0119 \u201eRestore View\u201d (Rys. 1.8g). Dlatego w dalszej cz\u0119\u015bci nie b\u0119dziemy ju\u017c wraca\u0107 do tej ikony.<\/p>\n\n\n\n<p>Jak wida\u0107, ten sam efekt mo\u017cna osi\u0105gn\u0105\u0107 na r\u00f3\u017cne sposoby. Kt\u00f3ry z nich jest lepszy? To ju\u017c decyzja badacza \u2014 wyb\u00f3r sposobu pracy ze stron\u0105 CleverView, kt\u00f3ry jest dla niego wygodny lub znajomy.<\/p>\n\n\n\n<p>Ikona z p\u0119dzlem \u2013 \u201eBrush\/Select Data\u201d (Rys. 1.8c). Aktywuj j\u0105 i, przytrzymuj\u0105c lewy przycisk myszy, zaznacz obszar, kt\u00f3ry chcesz wyr\u00f3\u017cni\u0107 innym kolorem (Rys. 2.16a), a nast\u0119pnie zwolnij przycisk myszy. Wynik pokazano na Rys. 2.16b. Aby usun\u0105\u0107 kolorowe pod\u015bwietlenie, wystarczy klikn\u0105\u0107 raz, trzymaj\u0105c kursor w obszarze t\u0142a (czarnego pola).<\/p>\n\n\n\n<figure class=\"wp-block-image size-full border\"><img data-dominant-color=\"5b5554\" data-has-transparency=\"true\" style=\"--dominant-color: #5b5554;\" loading=\"lazy\" decoding=\"async\" width=\"1474\" height=\"257\" src=\"https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-25.png\" alt=\"ECG segment highlighting in sector 4: dragging a rectangle over part of the curve to select it (a), and the resulting color-highlighted (red) segment after releasing the mouse button (b).\" class=\"wp-image-4594 has-transparency\" srcset=\"https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-25.png 1474w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-25-300x52.png 300w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-25-768x134.png 768w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-25-360x63.png 360w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-25-150x26.png 150w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-25-480x84.png 480w\" sizes=\"auto, (max-width:767px) 480px, (max-width:1474px) 100vw, 1474px\" \/><\/figure>\n\n\n\n<p class=\"doc-image-note\">Rysunek 2.16. Wynik dzia\u0142a\u0144 przy aktywnej ikonie \u201eBrush\/Select Data\u201d (wyja\u015bnienia w tek\u015bcie)<\/p>\n\n\n\n<p class=\"warning\">Ta funkcja jest przydatna, je\u015bli pracujesz nad jak\u0105kolwiek publikacj\u0105, niezale\u017cnie od platformy. Mo\u017cesz dostrzec tak\u017ce inne mo\u017cliwo\u015bci zastosowania tej funkcji. \u017byczymy Ci tw\u00f3rczych sukces\u00f3w i inspiracji do refleksji!<\/p>\n\n\n\n<p>Ikona przedstawiaj\u0105ca linie w oknie \u2013 \u201eData Tips\u201d (Rys. 1.8d). Przypominamy, \u017ce za jej pomoc\u0105 mo\u017cna ustali\u0107 wsp\u00f3\u0142rz\u0119dne interesuj\u0105cego nas punktu na krzywej. W tym celu aktywuj ikon\u0119, przesu\u0144 kursor w wybrane miejsce na krzywej, kliknij lewym przyciskiem myszy i uzyskaj okno ze wsp\u00f3\u0142rz\u0119dnymi (Rys. 2.17a). W razie potrzeby po\u0142o\u017cenie mo\u017cna skorygowa\u0107 strza\u0142kami \u201e&lt;\u201d i \u201e&gt;\u201d na klawiaturze. O\u015b \u201eX\u201d pokazuje czas, o\u015b \u201eY\u201d \u2013 amplitud\u0119 sygna\u0142u (dla EKG w naszej skali, w V (woltach)). Przytrzymuj\u0105c klawisz \u201eAlt\u201d, mo\u017cna umie\u015bci\u0107 dane dla wi\u0119kszej liczby punkt\u00f3w na krzywej (Rys. 1.17b).<\/p>\n\n\n\n<figure class=\"wp-block-image size-full border\"><img data-dominant-color=\"5d6260\" data-has-transparency=\"true\" style=\"--dominant-color: #5d6260;\" loading=\"lazy\" decoding=\"async\" width=\"1473\" height=\"303\" src=\"https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-26.png\" alt=\"Coordinate tooltips on a zoomed ECG curve showing the X (time) and Y (amplitude) values at one data point (a), and at a second point added by holding the Alt key while clicking (b).\" class=\"wp-image-4597 has-transparency\" srcset=\"https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-26.png 1473w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-26-300x62.png 300w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-26-768x158.png 768w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-26-360x74.png 360w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-26-150x31.png 150w, https:\/\/cleverpoint.pro\/wp-content\/uploads\/2026\/02\/image-26-480x99.png 480w\" sizes=\"auto, (max-width:767px) 480px, (max-width:1473px) 100vw, 1473px\" \/><\/figure>\n\n\n\n<p class=\"doc-image-note\"><br>Rysunek 2.17. Wynik dzia\u0142a\u0144 przy aktywnej ikonie \u201eData Tips\u201d (wyja\u015bnienia w tek\u015bcie)<\/p>\n\n\n\n<p><br>W naszym przyk\u0142adzie zaznaczyli\u015bmy na EKG dwa kolejne za\u0142amki R. Przypomnijmy, \u017ce obok niebieskiej linii oznaczaj\u0105cej za\u0142amek R poni\u017cej podana jest warto\u015b\u0107 chwilowego HR \u2013 dla drugiego \u201enaszego\u201d za\u0142amka R wynosi ona 84. Sprawd\u017amy to. Czas wyst\u0105pienia pierwszego za\u0142amka R wynosi 46,616 sekundy, drugiego \u2013 47,340 sekundy. Obliczamy czas trwania odst\u0119pu RR: 47,340 s \u2013 46,616 s = 0,718 s. Teraz obliczmy, jaka by\u0142aby warto\u015b\u0107 HR przy takim odst\u0119pie mi\u0119dzy kolejnymi skurczami serca: HR = 60\/0,718 = 83,6 uderze\u0144\/min, czyli \u2248 84 uderzenia\/min. Wniosek: obliczenie automatyczne jest prawid\u0142owe.<\/p>\n\n\n\n<p class=\"warning\">Przyk\u0142ad z obliczeniem chwilowej cz\u0119sto\u015bci akcji serca podano nie tyle w celu potwierdzenia poprawno\u015bci dzia\u0142ania CleverView, ile aby pokaza\u0107 jego mo\u017cliwo\u015bci w pracy z danymi cyfrowymi w badaniach naukowych.<\/p>\n\n\n\n<p>Kolejna ikona funkcyjna to \u201ePan\u201d (Rys. 1.8e). Aktywowanie ikony w kszta\u0142cie d\u0142oni powoduje pojawienie si\u0119 na ekranie odpowiadaj\u0105cego jej kursora. Praca z ni\u0105 jest bardzo prosta: umie\u015b\u0107 kursor na krzywej EKG, przytrzymaj lewy przycisk myszy i lekko przesuwaj mysz w r\u00f3\u017cnych kierunkach. Wszystko jest bardzo przejrzyste i, mamy nadziej\u0119, nie wymaga szczeg\u00f3lnych wyja\u015bnie\u0144, do czego s\u0142u\u017cy ta funkcja.<\/p>\n\n\n\n<p class=\"warning\">W dalszej cz\u0119\u015bci ikony funkcyjne b\u0119d\u0105 przywo\u0142ywane po nazwie.<\/p>\n\n\n\n<p>A my musimy i\u015b\u0107 dalej.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Sektor 4 wy\u015bwietla wykres automatycznie wykrytych za\u0142amk\u00f3w R na EKG, a po aktywowaniu odpowiedniej kom\u00f3rki w sektorze 1 (patrz Rys. 2.2a) wy\u015bwietla r\u00f3wnie\u017c sam\u0105 krzyw\u0105 EKG.<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"footnotes":""},"doc_category":[1426],"doc_tag":[],"class_list":["post-7401","docs","type-docs","status-publish","hentry","doc_category-rozdzial-2-cardio-domain"],"year_month":"2026-09","word_count":1112,"total_views":"12","reactions":{"happy":"0","normal":"0","sad":"0"},"author_info":{"name":"Vitaly","author_nicename":"vitaly","author_url":"https:\/\/cleverpoint.pro\/pl\/author\/vitaly\/"},"doc_category_info":[{"term_name":"Rozdzia\u0142 2. Cardio domain","term_url":"https:\/\/cleverpoint.pro\/pl\/docs\/rozdzial-2-cardio-domain\/"}],"doc_tag_info":[],"knowledge_base_info":[],"knowledge_base_slug":[],"_links":{"self":[{"href":"https:\/\/cleverpoint.pro\/pl\/wp-json\/wp\/v2\/docs\/7401","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cleverpoint.pro\/pl\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/cleverpoint.pro\/pl\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/cleverpoint.pro\/pl\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/cleverpoint.pro\/pl\/wp-json\/wp\/v2\/comments?post=7401"}],"version-history":[{"count":0,"href":"https:\/\/cleverpoint.pro\/pl\/wp-json\/wp\/v2\/docs\/7401\/revisions"}],"wp:attachment":[{"href":"https:\/\/cleverpoint.pro\/pl\/wp-json\/wp\/v2\/media?parent=7401"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/cleverpoint.pro\/pl\/wp-json\/wp\/v2\/doc_category?post=7401"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/cleverpoint.pro\/pl\/wp-json\/wp\/v2\/doc_tag?post=7401"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}